ASTM D2447 Test Data Product P/N SDR Nominal
IDMinimum
WallMinimum
WeightMaximum
WeightApprox.
Crush
StrengthApprox.
Tensile
StrengthCoeff. Of
Friction *(in) (in) (lb/100 ft) (lb/100 ft) (lb/ft) (lb) Static Kinetic 3/4"
3/4"105/40
105/80Sch. 40
Sch. 800.824
0.7420.113
0.15413.7
17.816.4
20.61000
17501100
14250.06-0.3
0.06-0.30.06-0.15
0.06-0.151"
1"131/40
131/80Sch. 40
Sch. 801.049
0.9570.133
0.17920.3
26.323.7
29.91150
19351625
21000.06-0.3
0.06-0.30.06-0.15
0.06-0.151-1/4"
1-1/4"166/40
166/80Sch. 40
Sch. 801.380
1.2780.140
0.19127.5
36.231.8
41.21025
18002200
29000.06-0.3
0.06-0.30.06-0.15
0.06-0.151-1/2"
1-1/2"190/40
190/60Sch. 40
Sch. 801.610
1.5000.145
0.20032.9
43.937.8
49.9975
17752640
35250.06-0.3
0.06-0.30.06-0.15
0.06-0.152"
2"237/40
237/80Sch. 40
Sch. 802.067
1.9390.154
0.21844.2
60.750.3
68.8900
17003550
48750.06-0.3
0.06-0.30.06-0.15
0.06-0.153"
3"350/40
350/80Sch. 40
Sch. 803.068
2.9000.216
0.30091.6
123.9103.4
140.41200
22257350
99500.06-0.3
0.06-0.30.06-0.15
0.06-0.154"
4"450/40
450/80Sch. 40
Sch. 804.026
3.8260.237
0.337130.4
181.1146.8
204.61150
222510500
145000.06-0.3
0.06-0.30.06-0.15
0.06-0.15Internal ribs will only have a minor effect on the tensile strength of the innerduct.
The static coefficient of friction for ribbed innerduct ranges from 0.10-0.32, while kinetic coeffecient of friction ranges from 0.04-0.18.* The values for coefficient of friction will vary depending on the material or product being pulled inside of the innerduct. For more specific information, please contact us at Endot.
Endot Industries, Inc., 60 Green Pond Road, Rockaway, NJ 07866
http://www.endot.com - e-mail: support@endot.com
(800) - 443-6368 | FAX: (973)625-4087