ASTM D2239 Test Data
Product P/N SDR Nominal
ID
Minimum
Wall
Minimum
Weight
Maximum
Weight
Approx.
Crush
Strength
Approx.
Tensile
Strength
Coeff. Of
Friction *
(in) (in) (lb/100 ft) (lb/100 ft) (lb/ft) (lb) Static Kinetic
3/4"
3/4"
3/4"
82/9
82/11.5
82/15
9
11.5
15
0.824
0.824
0.824
0.092
0.072
0.060
10.9
8.3
6.9
13.5
10.9
9.3
725
475
350
875
675
550
0.06-0.3
0.06-0.3
0.06-0.3
0.06-0.15
0.06-0.15
0.06-0.15
1"
1"
1"
1"
105/7
105/9
105/11.5
105/15
7
9
11.5
15
1.049
1.049
1.049
1.049
0.150
0.117
0.091
0.070
23.2
17.6
13.4
10.1
26.8
21.0
16.6
13.2
1400
925
600
375
1865
1400
1075
815
0.06-0.3
0.06-0.3
0.06-0.3
0.06-0.3
0.06-0.15
0.06-0.15
0.06-0.15
0.06-0.15
1-1/4"
1-1/4"
1-1/4"
125/9
125/11.5
125/15
9
11.5
15
1.250
1.250
1.250
0.150
0.110
0.080
27.1
19.3
13.7
31.2
23.2
17.4
1250
725
400
2175
1550
1100
0.06-0.3
0.06-0.3
0.06-0.3
0.06-0.15
0.06-0.15
0.06-0.15
1-1/4"
1-1/4"
1-1/4"
1-1/4"
138/7
138/9
138/11.5
138/15
7
9
11.5
15
1.380
1.380
1.380
1.380
0.197
0.153
0.120
0.092
40.1
30.3
23.2
17.5
45.7
34.7
27.5
21.6
1800
1200
785
500
3200
2430
1850
1400
0.06-0.3
0.06-0.3
0.06-0.3
0.06-0.3
0.06-0.15
0.06-0.15
0.06-0.15
0.06-0.15
1-1/2"
1-1/2"
1-1/2"
161/9
161/11.5
161/15
9
11.5
15
1.610
1.610
1.610
0.179
0.140
0.107
41.3
31.6
23.7
46.5
36.6
28.5
1400
915
575
3300
2540
1900
0.06-0.3
0.06-0.3
0.06-0.3
0.06-0.15
0.06-0.15
0.06-0.15
2"
2"
2"
206/9
206/11.5
206/15
9
11.5
15
2.067
2.067
2.067
0.230
0.180
0.138
68.2
52.2
39.3
77.4
59.2
45.4
1800
1200
725
5500
4200
3150
0.06-0.3
0.06-0.3
0.06-0.3
0.06-0.15
0.06-0.15
0.06-0.15
3"
3"
307/11.5
307/15
11.5
15
3.068
3.068
0.267
0.205
115.0
86.6
130.0
95.7
1750
1100
9200
7000
0.06-0.3
0.06-0.3
0.06-0.15
0.06-0.15
4" 403/11.5 11.5 4.026 0.350 197.8 223.6 2300 16000 0.06-0.3 0.06-0.15

Internal ribs will only have a minor effect on the tensile strength of the innerduct.
The static coefficient of friction for ribbed innerduct ranges from 0.10-0.32, while kinetic coeffecient of friction ranges from 0.04-0.18.

* The values for coefficient of friction will vary depending on the material or product being pulled inside of the innerduct. For more specific information, please contact us at Endot.

Endot Industries, Inc., 60 Green Pond Road, Rockaway, NJ 07866
http://www.endot.com - e-mail: support@endot.com
(800) - 443-6368 | FAX: (973)625-4087